Tip: To calculate the appropriate pressure regulator: according to the standard, the flow of the regulator must be so large that when operating all consumers at the same time, the flow rate of the regulator is greater than the consumption. Example: 2-burner stove 232 g/h, heater E2400 200 g/h, boiler 120 g/h = consumption: 552 g/h >regulator with 0.8 kg/h flow rate.
Cut-off pressure: | 16 bar |
gas pressure: | 30 mbar |
Gas: | LPG |
Controller output: | 0.8 kg/h |